Ruggedization & Cooling

At CES, we develop all our products to deliver the highest performance within the harsh environmental constraints that are characteristic of Aerospace & Defense applications. This includes extreme temperatures, shocks, vibration and humidity.

Our in-house manufacturing and testing capabilities allow us to monitor quality and verify, at board level, each product in a test environment simulating typical operational conditions. For our customers, this is the guarantee of controlled operational boundaries which they can count on to meet their system-level requirements.

Depending on the operational environment of the boards, we define four ruggedization levels following industry standards, like the VITA-47, and established best practices of the industry.

The migration process from air-cooled commercial equipment to rugged conduction-cooled equipment requires no additional development and is 100% compatible both in terms of hardware and software. Typical projects are developed on laboratory, cost saving, equipment which then enables you a smooth program deployment.

The following table summarizes the four ruggedization levels defined by CES for board-level COTS products. Other variants may be available as custom or modified COTS products based on your specific requirements. Environmental Stress Screening (ESS) can be provided as an additional service.

CES LevelDescriptionCooling TypeOperating TemperatureVibration (1 hour per axis)Operating Shocks
A1General Purpose ACForced Air*0°C to 55°C [AC1]5-100 Hz: increase at 3 dB/octave, 100-1000 Hz: 0.04 g2/Hz, 1000-2000Hz: decrease at 6 dB/octave [V2]20g, 11ms saw-tooth, three axes [OS1]
A3Rugged ACForced Air*-40°C to 70°C [AC3]5-100 Hz: increase at 3 dB/octave, 100-1000 Hz: 0.04 g2/Hz, 1000-2000Hz: decrease at 6 dB/octave [V2]20g, 11ms saw-tooth, three axes [OS1]
C3Rugged CCConduction-40°C to 70°C [CC3]5-100 Hz: increase at 3 dB/octave, 100-1000 Hz: 0.1 g2/Hz, 1000-2000Hz: decrease at 6 dB/octave [V3]40g, 11ms saw-tooth, three axes [OS2]
C4Extended Range CCConduction-40°C to 85°C [CC4]5-100 Hz: increase at 3 dB/octave, 100-1000 Hz: 0.1 g2/Hz, 1000-2000Hz: decrease at 6 dB/octave [V3]40g, 11ms saw-tooth, three axes [OS2]

*The required air-flow is defined separately for each product.

Additional environmental specifications, valid for all COTS products, are given in the following table.

ConditionLimits, standardsComments
Non-operating temperature-55°C to 105°C [C4]
Humidity95%
Altitude-1’500 to 60’000 feetMay require conformal coating.
Fungus resistanceNo nutrient materials
WorkmanshipIPC-A-610 class 3
SolderingIPC J-STD-001 class 3
PCB ManufacturingIPC-A-600 class 3
Conformal coatingIPC-CC-830Optional
MaterialsREACH compliantROHS variants as an option
FlammabilityUL 94 Class V-0
QualityEN 9100:2008