At CES, we develop all our products to deliver the highest performance within the harsh environmental constraints that are characteristic of Aerospace & Defense applications. This includes extreme temperatures, shocks, vibration and humidity.
Our in-house manufacturing and testing capabilities allow us to monitor quality and verify, at board level, each product in a test environment simulating typical operational conditions. For our customers, this is the guarantee of controlled operational boundaries which they can count on to meet their system-level requirements.
Depending on the operational environment of the boards, we define four ruggedization levels following industry standards, like the VITA-47, and established best practices of the industry.
The migration process from air-cooled commercial equipment to rugged conduction-cooled equipment requires no additional development and is 100% compatible both in terms of hardware and software. Typical projects are developed on laboratory, cost saving, equipment which then enables you a smooth program deployment.
The following table summarizes the four ruggedization levels defined by CES for board-level COTS products. Other variants may be available as custom or modified COTS products based on your specific requirements. Environmental Stress Screening (ESS) can be provided as an additional service.
| CES Level | Description | Cooling Type | Operating Temperature | Vibration (1 hour per axis) | Operating Shocks |
| A1 | General Purpose AC | Forced Air* | 0°C to 55°C [AC1] | 5-100 Hz: increase at 3 dB/octave, 100-1000 Hz: 0.04 g2/Hz, 1000-2000Hz: decrease at 6 dB/octave [V2] | 20g, 11ms saw-tooth, three axes [OS1] |
| A3 | Rugged AC | Forced Air* | -40°C to 70°C [AC3] | 5-100 Hz: increase at 3 dB/octave, 100-1000 Hz: 0.04 g2/Hz, 1000-2000Hz: decrease at 6 dB/octave [V2] | 20g, 11ms saw-tooth, three axes [OS1] |
| C3 | Rugged CC | Conduction | -40°C to 70°C [CC3] | 5-100 Hz: increase at 3 dB/octave, 100-1000 Hz: 0.1 g2/Hz, 1000-2000Hz: decrease at 6 dB/octave [V3] | 40g, 11ms saw-tooth, three axes [OS2] |
| C4 | Extended Range CC | Conduction | -40°C to 85°C [CC4] | 5-100 Hz: increase at 3 dB/octave, 100-1000 Hz: 0.1 g2/Hz, 1000-2000Hz: decrease at 6 dB/octave [V3] | 40g, 11ms saw-tooth, three axes [OS2] |
*The required air-flow is defined separately for each product.
Additional environmental specifications, valid for all COTS products, are given in the following table.
| Condition | Limits, standards | Comments |
| Non-operating temperature | -55°C to 105°C [C4] | |
| Humidity | 95% | |
| Altitude | -1’500 to 60’000 feet | May require conformal coating. |
| Fungus resistance | No nutrient materials | |
| Workmanship | IPC-A-610 class 3 | |
| Soldering | IPC J-STD-001 class 3 | |
| PCB Manufacturing | IPC-A-600 class 3 | |
| Conformal coating | IPC-CC-830 | Optional |
| Materials | REACH compliant | ROHS variants as an option |
| Flammability | UL 94 Class V-0 | |
| Quality | EN 9100:2008 |